POWER TECH SYSTEM

                                               AC DRIVES & ALL KIND OF AUTOMATIONS

POWER TECH SYSTEM
22,Shukan Mall,Science City Road
Ahmedabad, Gujarat 380060

ph: +91-79-65242588
fax: +91-79-27460702
alt: +91-9824320976

Q9000

Q9000 (High Performance Vector Control Inverter For General Purpose)Q9000 Photo

  • INTRODUCTION

    Q9000 High Performance vector inverter
    Q9000 Series is a kind of high performance universal vector control
    inverter. Current vector technology and advanced modern control theory are used to provide more torque in operation at low speed and achieve high performance dynamic control. There are four control modes to select. Even without PG vector control, it can obtain a high torque and failure-free operation from a low speed at 1%; While with PG control, it can easily obtain high torque operation at 0 speed, which is the ideal choice for you to improve the quality and productivity.

  • FEATURES


    Perfect Current Vector Control
    By means of simultaneously controlling the primary current and its phase, the magnetic field current and torque current can be controlled respectively and individually to obtain a smooth run, a speed control and torque control with high torque and high precision at a very low speed

    Various Control Functions
    PID control, slip compensation function, speed search, over/lower torque detection and energy-saving operation control function

    Excellent Torque Characteristics
    Even if without PG, a high torque of 150%/0.5Hz can be reached

    Powerful Braking Function
    Powerful braking function can be fulfilled with built-in braking units for the
    inverterbelow 15kw and external braking resistors for that above 15kw

    Hi-efficiency Energy-saving control
    Wonderful energy-saving function beyond imagination, the hi-efficiency energy-saving control reaches the maximum effect in theory

    Low Noise Operation
    High carrier frequency SPWM modulation type may greatly suppress the noise, which is especially suitable for the place with limitation for noise.

    Perfect Power Ultraharmonics Suppression Countermeasures
    Built-in DC reactor for the purpose of improving power factors is equipped for all series of 55kw and above; DC reactor wiring terminal is reserved for the units below 55KW for your choice of DC reactor to reduce the interference of the ultraharmonics of power.

  • OTHER FUNCTIONS

    * Powerful Q9000 may satisfy various needs of different users
    * Standard built-in PID feedback control may provide a precise closed loop control
    * V/F separation and free V/F image function may fully meet any special requirements of various motors
    * Powerful autotuning function enables all kinds of motors to run effectively
    * Whatever precise machinery or multi-motor operation, there are four control modes combined closely to fulfill best running
    * High torque at low speed and smooth acceleration/deceleration in whole frequency domain
    * Simple and flexible operation is suitable for various operating conditions
    * Expanding function applies to stand-alone or network
    * Independent programming satisfies any special requirements of the customers well.
    * The built-in PG card is suitable for incremental encoder of any brands, including HEIDENHAN, NEMICON, etc
    * Self-check protection function will give out corresponding fault indication and stop the output of the
    inverterat the same time when the parameter is not correct.
    * It can run by autotuning of the
    inverterthat may measure the distance between two sections automatically
    * The operation of the
    invertercan be counted and controlled by the velocity curve to obtain rectilinear stop and high positioning precision
    * The speed signal supports multiple speed control and analog signal control
    * Vibration at high speed or low speed can be compensated
    * S running curve and the startup time or stop time for deceleration or deceleration can be set freely
    * Easy to install and debugging and compatible with Yaskawa series
    inverter, which can be replaced directly

  • SPECIFICATIONS

     

    440V
    Type
    HP
    3
    5
    5.5
    7.5
    10
    15
    20
    25
    30
    40
    50
    60
    75
    100
    120
    150
    180
    200
    250
    300
    340
    400
    Rated Output
    Motor power
    KW
    2.2
    3.7
    4
    5.5
    7.5
    11
    15
    18.5
    22
    30
    37
    45
    55
    75
    90
    110
    132
    160
    185
    220
    250
    315
    Rated power
    KVA
    4.7
    6.1
    8
    11
    14
    21
    26
    31
    37
    50
    61
    73
    98
    130
    150
    170
    202
    230
    260
    340
    370
    460
    Rated current
    A
    6.2
    8
    9
    14
    18
    27
    34
    41
    48
    65
    80
    96
    128
    165
    183
    224
    264
    302
    340
    450
    510
    630
    Output voltage
    V
    Three-phase 380/415/440/460V (Proportional to input voltage)
    Max. output frequency
    Up to 400Hz available by programming
    Power
    Rated voltage and frequency
    Three-phase 380~460V, 50Hz/60Hz
    Allowable voltage fluctuation
    +10%~-15%
    Allowable frequency fluctuation
    ±5%
    220V
    Type
    HP
    3
    5
    7.5
    10
    15
    20
    25
    30
    40
    50
    60
    75
    100
    150
    Rated Output
    Motor power
    KW
    2.2
    3.7
    5.5
    7.5
    11
    15
    18.5
    22
    30
    37
    45
    55
    75
    110
    Rated power
    KVA
    4.2
    6.7
    9.5
    13
    19
    24
    30
    37
    50
    61
    70
    85
    110
    160
    Rated current
    A
    11
    17.5
    25
    33
    49
    64
    80
    96
    130
    160
    183
    224
    300
    450
    Output voltage
    V
    Three-phase 200/220/230/240V (Proportional to input voltage)
    Max. output frequency
    Up to 400Hz available by programming
    Power
    Rated voltage and frequency
    Three-phase 220~2400V, 50Hz/60Hz
    Allowable voltage fluctuation
    +10%~-15%
    Allowable frequency fluctuation
    ±5%
    Control Feature
    Control method
    Sine wave PWM dynamic current vector control (with V/F control, torque vector control, PG feedback vector control)
    Speed control accuracy
    ±0.2%
    [±0.02% with PG]
    Speed control range
    1:100
    [1:1000 with PG]
    Speed control response
    10Hz
    [30Hz with PG]
    Starting torque
    150%/0.5Hz
    [200%/0Hz with PG]
    Torque response
    20Hz, 50ms
    [40Hz, 25ms with PG]
    Torque accuracy
    ±5%
    Torque limit
    4 kinds of vector control methods by parameter setting
    Frequency controlling range
    0.01~400 Hz
    Frequency accuracy
    Digital signal reference: ±0.01% (-10℃~ +40℃), analogue reference: ±0.1% (25℃±10℃)
    Frequency setting resolution
    Digital signal reference: ±0.01Hz (Below 100Hz), analogue reference: ±0.03Hz/60Hz (12bit)
    Output frequency resolution
    0.001 Hz
    Frequency setting signal
    Analogue reference DC-10~+10V (20KΩ), 4~20mA (250Ω)
    Braking torque
    ±20 % (approximately 150% with braking resistor option)
    Accelerating/Decelerating time
    0.01-6000.0s (Accelerating/Decelerating time setting independently, 4 kinds of time controlling modes available)
    Overload capability
    150% of Rated torque current for 60s, 200% of rated torque current for 10s
    Communication
    RS-485
    Running/stopping setting
    Operator, RS-485, Control circuit terminal (frequency setting and parameter access control available by computer)
    Affiliated control function
    Parameter save operator, RS-485, torque control, speed control, PID control, multiple-speed control, couple control, etc.
    Protective Function
    Instantaneous overcurrent
    Motor coasts to stop at approx. 200% rated output current.
    Motor overload protection
    Electronic thermodynamic electric protection
    Fuse protection
    Motor coasts to stop
    Momentary power loss
    Continue to runduring power loss less than 2s (standard)
    Overload
    150% of rated output current for 60s, 200% of rated output current for 10s, motor coasts to stop
    Fin overheat
    Thermocouple temperature switch protection
    Stall prevention
    Stall prevention during acceleration/deceleration and constant speed operation
    Ground fault
    Protected by electronic circuit
    Power charge protection
    Indicates until the main circuit voltage reaches 50 V

     

Copyright 2009 FREQUENCY INVERTER. All rights reserved.

Web Hosting by Yahoo!

POWER TECH SYSTEM
22,Shukan Mall,Science City Road
Ahmedabad, Gujarat 380060

ph: +91-79-65242588
fax: +91-79-27460702
alt: +91-9824320976